Battery Breif

Cindy / 2013-12-29
[B] [M] [S]

 The choose of the Battery

WS serials wind turbine generator is one kind of off grid device. So battery is necessary and important auxiliary equipment with the function of power storage and voltage stabilization in the system. 

There are many kinds of batteries, such as lead-acid battery,cadmium-nickel storage battery,Fe-Ni battery,zinc - silver battery,Nickel zinc battery,  nickel-hydrogen battery,lithium-ion battery and so on. Among those kinds, except lead-acid battery, all others are of high price and difficult to purchase.So we recommend to use lead-acid battery in our WS serials wind turbine generators.

There are two main types of lead-acid battery. One is open cell(vented cell), it is necessary to replenish electrolyte and add water regularly. It releases Hydrogen and Oxygen when charging which will led to explosion after long time collecting in the small and poor ventilation space.Besides, it has a short life time.The other type is Valve-control Sealed battery. Since it is sealed, so it will not overflow acidity electrolyte even if it tripped. And it it maintenance free battery with little Hydrogen and Oxygen release,as well as no acid fog spilt.Also it is of long life time. So, hope the user choose valve-control sealed lead-acid battery.

1.2 The correct usage of the battery

The design life of valve-control sealed lead-acid battery in market is ten years, In actual, there are so many factors effecting the life of it. The wrong use of it also will reduce its life time. The main factors shown as below:

1) The high environment temperature seriously effects the life time of the battery. The corrosion of plate increases as the rising of the temperature. Thus reduces the life of it. The best working temperature is 20℃.

2) It will also increase the corrosion of the plate in the condition of over charging for long time.while in over discharging for long time,the inner resistance will enlarge,which will result from the worse and worse charging and discharging function.

3) Under float charging long term(only charging but no discharging),the plate will make deactivation and its capacity decrease.

   

In the usage and maintenance of valve-control sealed battery should pay attention to below notes based on the above factor.

1) Carefully read the instruction of the battery.

2) Battery bank should be put at ventilation and dry place and far from heat source and flame. The distance between two of them should be at least 50mm. And use it at 15℃~25℃ as long as possible.

3) The correct connection and operation of controllers and inverters could effectively prevent the battery overcharging and overdischarging.

4)  The power of the load which connects the out put of the inverter should be smaller than that of the wind generator. And do not connect the electric apparatus with larger start current as long as possible.

5) The battery should be disconnected the controllers if long time no use . Thus avoid the the battery on floating charge for long time.

6) The battery with different manufacture,model,kind,capacity as well as old and new grade can not be inseries or in parallel.

1 Cautions

1) The working temperature of controllers and inverters are -10~+45℃、0~+40℃ desperately. The relative humidity of both is under 80% . Please stop inverter at 40℃,while at 45℃, please stop controller immediately.

2).There are exposed wires on controllers,inverters and batteries. Any conduct objects can not be touched at those wires.

3).In order to avoid electric stock accident and equipment damage,children and related people should be told not to touch and play controllers,inverters and batteries

4).To keep the controllers,inverters and batteries in the good ventilation,dry environment, they can not be exposed directly in rain, snow and fog. And can not be wiped with wet rag.

5).the power of the load connected on the out put of the inverter can not be larger than the rate power of inverter. Before connect with the electric applications, please first close the air break switch,then close the output switch of the inverter.

6).When too large of the power of electric equipment will make the device and electric cable over heated, thus occur fire.

7).When found the wind is too strong or foresee the wind speed will be above a force 10 wind, then please hook the circular hole on tail using a hook with rope, pull the turbine to the direction vertical with the wind and fix the rope, avoid people approaching the turbine at the same time.

8).During the malfunction and maintenance of controller,please do not let the output wire on short-circuit or break long time. You could connect a power resistor could afford 1000w.3Ω. You could also connect the output wire connect directly the input of the inverter.

9).Please note special for the short-circuit of the battery,otherwise will damage the battery and cause fire.

10).Check and repair circuity when working, should first close air break switch, then close the output switch of inverter, at last cut the connected wire of the wind turbine from controller.Never cut the battery wire from controller at first,otherwise the controllers will be damaged.

11).If the wind is mall at long term, should stop the inverter,avoid the battery on shortage of power long time. Otherwise will reduce the life time of the battery.

12).High attention,never connect the output of inverter with the main electricity circuitry,otherwise will burn out the whole equipment of the wind turbine system.

13).When inverter working under the larger load,the temperature of the inverter case may up to 60℃, so should put the inverter in a loose space , at least 100mm. Do not put it on the surface of the combustibles and avoid touch their surface when the inverter is working.

14).The electric applications using chargeable Ni-Cd battery can not be connected on the output of the inverter. Such as flashlight,shaver,power tool etc. Otherwise will damage those applications. 

      

11.Special Note

Do not disassemble and repair wind turbine, controller,inverter by yourself, otherwise will loss the warranty.   

Do not use the wind turbine generator and device this manual described on the life support system of hospital.

12.Common Troubleshooting Guide

 

failure phenomenon

Possible failure reason

troubleshooting methods and procedures

Above a force 4 wind,but blates turn slow,the charge indicator light does not shine

1.the output of the wind turbine short-circuit

2.the motor inner failure

1.check if the connection terminals on the controller short-circuit.if so, please reconnect them.

  

2.if the connection terminals are not short-circuit,or still failure after reconnection. Close the output switch of inverter at first then removal the connection wire of battery bank from controller,take measures to prevent the battery connect wire short circuit.Removal the output wire of wind turbine from controller, With a multimeter to measure the resistance between the output lines,if there is no resistance or small resistance,then indicate that connection cable internal short-circuit,then check the short circuit part and remove it.

3.if the above check is normal, then need replace generator

wind is weak,but blates turn fast,the charge indicator light does not shine

1.the output of the wind turbine break

2.the motor inner failure

1.check if the connection terminals on the controller break.if so, please reconnect

2.if the connection terminals are not break,or still failure after reconnection. Close the output switch of inverter at first then removal the connection wire of battery bank from controller,take measures to prevent the battery connect wire short circuit.Removal the output wire of wind turbine from controller, make the two terminal of the output short-circuit .observe if the blades turn slow,if so,need to change the generator,if still fast turn, with a multimeter to measure the resistance between the output lines,if there is no resistance,then indicate that connection cable internal break,then check the break part and remove it.

3.after checking the above trouble,the failure remains, then need replace generator

the blades stirs dithering

blades of the mounting bolts loose

upend the pole, re-tighten the bolt

the blades turn normally,but can not charging the battery

1.rontroller fuse burnout

2.controller is burnout

3.the motor inner failure

1.removal the wind turbine output wire from controller,unplug the fuse from the rear panelof controller, check if the fuse break,if so, please change fuse.

2.if the failure still remain after change and reconnection. Then removal the output of wind turbine ,measure the voltage between the output wires with a multimeter, if normal,need to change or repair the controller,if no voltage,need change or repair generator.

inverter tweet, electrical equipment does not work, light does not shine

1.the voltage of the battery is too low

2.the load is too large

1.close the output switch of inverter, reopen it after the wind turbine works for some time.

2.if the voltage of the battery is normal,then close some big power applications.

inverter does not work, no AC output

1.the positive and negative poles  of the cable reversed or cable joints loose

2.the battery damaged

1.check the connection of the cable

2.check if the battery can charge on the condition that the wind turbine and controllers work normally. If not or maybe the battery used too many years, so need change battery.

low voltage of inverter output 

low voltage of wind turbine or battery

stop use inverter, reopen it when the wind is strong or after the battery finishes charging.

inverter tweet, 

1.low voltage of battery

2.overheat of inverter

1.stop using inverter, reopen it when the wind is strong or after the battery finishes charging.

2.stop using inverter,reopen it after cooling.if this happens repeatedly,put the inverter to the good ventilation and coolant place.  

inverter failure indicate light shine,and tweet at the same time

1.the load connected on the output of inverter is too large

2.the start circuit of electric application is too large

3.the voltage of the battery is too low

4.overheat of inverter

5.too high output voltage

1.reduce the use of big power applictions

2.replace the big startup circuit of application with small startup circuit.

3.stop using inverter, reopen it when the wind is strong or after the battery finishes charging.

4.stop using inverter,reopen it after cooling.if this happens repeatedly,put the inverter to the good ventilation and coolant place. 

5.check if the voltage of the battery bank is normal or not

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

View History

vedio center products center Honor Knowledge Outstanding Articles
Bluelight History  |  About Us  |  Honor  |  Knowledge  |  Feedback  |  Service  |  Company profile  |  Contact Us

© 2005-2017 Wellsee solar supply Copyright, All Rights Reserved.
Wuhan Wellsee New Energy. Block D, Zhongli Enterprise Building, No. 92, Wuhan Boulevard, Wuchang District, Wuhan, Hubei, China
Tel: 0086-13986203125,13986203097,13971182531 E-mail: sales@e-bluelight.com,admin@e-bluelight.com
skype:Cindy
cindywellseeCindy cindywellsee  skype:Doris
doriswellseeDoris doriswellsee  skype:Tracy
tracywellseeTracy tracywellsee  skype:Owen
sarawellseeOwen sarawellsee