Pure Sine Wave Inverter User Manual

 

 

Catalogue

 

0. Preface

1.       Safty instruction warning

2.       Installation

3.       Inverter operation program

4.       Inverter working principle

5.       Inductive digram

6.       Ways to tackle different conditions.

7.       Technical parameters

8.       Inverter repair and manintence

 

Pls strictly follow the instructions in the user manual and take care of it.

Don’t operate the machine in the absence of safty operations and instructions, or it will break the machine and result in physical security incidents.

 

 

PREFACE

This series inverter is our company most developed pure sine wave. Sine the launch in early 2003, after the market feedback and continuous improvement, it has been perfect and a lot of electricity exported to the poorest India, Iraq and other countries. Product quality has been tested.

Shown in the following aspects:

1) Completely controlled by CPU, and it is unique throughout the world, when you increase the stability of the inverter, it reduces its costs.

2) Super wide input voltage: 90v-280v with four step AVR built-in. 3) Protections against output short-circuit; against overload, high voltage and low voltage protection , over heating protection, battery anti-polarity protection. Etc.

4) With different DC voltage, such as 12V, 24V, 36V, 48V, 72V, 96V, 220V, 240V, 110V, (optional).

5) With RS232 software, SNMP card(optional)

6) LCD display or LED display (optional).

7) Output voltage AC: 220v, 230v, 240v (optional).

8) With charger built-in. The charger is controlled by CPU, charging current for 500W-1000W is about 10A --- -25A (adjustable).

9) With driving inductive loads capability, such as fridge, TV, air-conditioner, washing machine, micro-oven wave, motor and so on.

 

 

SAFE INSTRUCTION WARNING

Definition of security

 

In this manual, safety precautions under the following two categories:

risk
In the absence of the required operating hazards could result in serious injury.
Note
In the absence of the required operating hazards, may lead to moderate injury or minor injury and equipment damage and so on.
First, security issues
1, installation
I. Install away from combustible materials, or may cause fire.

. Inverter Used to connect the battery, the battery should be installed in the battery box, can not be placed indoors bare.

Second, when wiring

risk

1.The equipping wiring of 12KW inverter should be done by professional technician, or a risk of electric shock.

2. Pls note whether the power is disconnected or not before wiring, or there will be electric shock.

3. External battery may not short circuit, or will cause significant harm to people and damage the equipment.

Note
Must pay attention to the inverter battery cables, positive (red) can only be connected battery, negative (black) can only access the battery negative, otherwise it will damage the inverter and  not in the warranty.
Note: Do not pour water and other liquid debris inside the inverter, or cause equipment damage
Bad.

 

INSTALLATION

1.The inverters is equipped with power input socket, as long as plug the inverter input power into the mains socket.

a) First make sure the battery is connected correctly and firmly, if unfirm, it’s prone to battery ignition phenomenon and will damage the inverter.

b) Check whether the battery voltage with the inverter input DC voltage is compatible, the inverter battery cable(red is positive, black is negative) are connected to the battery positive and negative.

c) Start pressing the inverter, after the inverter inversion is normal( yellow light is on), plug the entrance power plug into the mains outlet to complete starting machine.

 

2.Installation of inverter to no distribution mains input socket.
a)Electrical wiring must be requested by inverter wiring.

Model

3KW

35KW

4KW

7KW

10KW

15KW

Equipped wiring requirement

2 mm2

2.5mm2

4 mm2

6 mm2

8mm2

12 mm2

 

b)Wiring digram:

 

 

c) First connect the external battery, make sure the battery is connected correctly and firmly.

d) 2KW-4KW DC voltage is 48V, that is four pcs batteries connected in series, 5KW-10KW is 96V or 240V, mark according to the subject on the machine.

e) By electrical standards, connect the input and output lines to the electricity grid.

f) Then connect the machine’s battery cable to the positive and negative extreme  of the external battery.(Red positive, Black negative).

g) Press the start switch, after the inverter working normally, then the yellow light is on, and close the electricity input switch.

ATTENTION

If don’t follow the above instructions, it may damage the equipment, this is not in the warranty.

 

INVERTER OPERATION PROGRAM

1. Inversion operation at battery mode

First access the required battery pack to the inverter, press the power button ( on), we will hear the machine tweet, then the machine is into the self-test(city lights flashing, this process about three seconds). Inverter indicator light is on that means self –test completed. Note the machine operates normally, this time the inverter output is steady pure sine wave voltage of 220V, AC load equipment can be connected at this time.

2.Inverter operation at municipal electricity

Access the required battery pack to the inverter, then enter the electricity, the machine starts automatically.

3.Proper close procedure

Press the shutdown button(OFF) about three seconds( if any electricity, should disconnect the electricity input, and then do this, otherwise it will damage the inverter), the machines shuts down normally.

Warning: The above steps must be strictly in accordance with the order.

 

INVERTER WORKNG PRINCIPLE

a)       Normal operation

Input power is normal, inverter output power from the main inut power output provided by the bypass, while also charging the battery.

b)       Battery running

The main input power disconnected, the load from the battery-powered inverter, or when the main input supply voltage is too high or too low, in this case the inverter will automatically switch to battery power.

Note: Due to load power relates with discharging time, the battery will be damaged to reduce efficiency by cold or high temperature, we can disconnect some of the load to extend the time of power. When input power, power supply disconnects, the alarm will be ringing on and on. When the battery is discharged to the critical termination voltage(END OF DURATON PRE-ALARM), alarm sound frequency speeds, the best way is to end all onging work. When the primary input power to power failure, battery depletion, inverter stops power supply. When the main power is restored, inverter will offer the electricity, the same inverter to charge the battery automatically.

c)       CPU

Control of the inverter operation status.

d)       Battery

Provide backup power for the inverter, depending on the backup time, maching different capacity of batteries.

e)       Inverter

Inverter output section, transfer DC voltage or DC battery voltage of  the rectifier into a stable sine wave AC voltage, in normal circumstances, the inverter output section is powered by the bypass.

f)        Inverter bypass

In the normal case input electricity, the load will be powered by static bypass switch. At this point, if the main input power failure, the output

will be battery-powered, so the load keeps working.

Note:

The inverter is maintenated by professional technicians, input and battery switch has power in case of disconnecting. Non professional personnel will not noly damage the inverter devices , but also hurt personnel.

 

INTELLIGENT INVERTER WITH INDUCTIVE LOADS LIST

WS-P500

500W

TVEmergency lightingcomputer

WS-P700

700W

TVEmergency lightingcomputer

WS-P1000

1KW

Fridge,  TV, Emergency lightingcomputer

WS-P1500

1.5KW

1P air conditioner,  Emergency lightingcomputer

WS-P2000

2KW

1.5P air conditioner, Emergency lighting, computer fridge and washing machine

WS-P2500

2.5KW

1.5P air conditioner, Emergency lighting, TV,computer fridge and washing machine

WS-P3000

3KW

1.5P air conditioner, Emergency lighting, computer fridge and washing machine

WS-P3500

3.5KW

1.5P air conditioner, Emergency lighting, computer fridge and washing machine

WS-P4000

4KW

1.5P air conditioner, Emergency lighting, computer fridge and washing machine

WS-P7000

7KW

Emergency equipmentcomputerfridgeair conditioneremergency lightingelectric motor

WS-P10000

10KW

Emergency equipmentcomputerfridgeair conditioneremergency lightingelectric motor

WS-P15000

15KW

Emergency equipmentcomputerfridgeair conditioneremergency lightingelectric motor

Note: The inverter is not recommended long term operation with full load, otherwise it will affect their life, the best way is 80% for the best.

 

TACKLE LIST FOR DIFFERENT CONDIDITONS

Fault display

Phenomenan

solution

Green light on

Red light on

Inductive load overloadwhen transfer to battery offering power, inverer will lock automatically, no output.

Reduce load

Yellow light on

Inversion condition

normal

Green light on

Yellow light flicker

charging

normal

Red light on all the time

Yellow flicker

Battery pack wrong

Check battery connecting wire is loosing or not, short circuit, low battery voltage or damage.

Red light on all the time

Green light flicker

Output with short circuit

Check output load is short circuit or not

Red light on

fault

Contact with manufactuer

Fault display

Phenomenan

solution

 

 

 

 

 

 

 

Technical parameters:

Model

WS-P500

WS-P700

WS-P1000

WS-P1500

WS-P2000

WS-P2500

Power

500W

700W

1000W

1500W

2000W

2500W

Input voltage

175—265Vac(optional 90V~300V output range   Export machine type)

Input frequency

50HZ±5HZ

Inversion output voltage

220VAC±3%

Inversion output frequency

50HZ±2%

DC voltage

12V

24V

48V

Output waveform

Pure sine wave

THD

≤3%

Transfer time

≤4ms automatic transfer

Charging current

Average charging current 8A500W); 10A700-2000W

Max charging current 10A500W); 18A700-2000W

CPU controll charging intelligent charging

Overload protection

Overload 100—120%automatically lock after 25soverload 120—200%automatically lock after 1sexceed200%automatically lock after 0.1.

Dimension

372*122*203

405*145*220

460*194*305

                 

 

Model

WS-P3000

WS-P3500

WS-P4000

WS-P4000

WS-P10000

WS-P15000

Power

3000W

3500W

4000W

7000W

10KW

15KW

Input voltage

175—265Vac

Input frequency

50HZ±5HZ

Inversion output voltage

220VAC±3%

Inversion output frequency

50HZ±2%

DC voltage

48V

96V

Output waveform

Pure sine wave

THD

≤3%

Transfer time

≤4ms automatic transfer

Charging current

Average charging current 10A

Max charging current 18A

CPU controll charging intelligent charging

Overload protection

Overload 100—120%automatically lock after 25 soverload 120—200%automatically lock after 1sexceed 200%0.1s automatically lock.

Dimension

460*194*305

550*255*700

Weight kg

76

100

105

180

234

280

                   

 

INVERTER REPAIR AND MAINTANCE

(A) Regular maintenance

Inverter’s only need for regular inspection of the battery and the fan.

1.       fans require regular inspection and cleaning.

2.       Any battery replacement should be carried out by professional. The replaced battery must be sent to recalling palce, according to the law identified as” toxic waste”. Battery life according to operating temperature, determined by the number of discharge cycles, at 20 degrees celsius, the average battery life is about 3 to 5 years, if the ambient temperature is above 30 degrees centigrade, the battery life will be halved, the battery capacity will remain stable after the chagrge and discharge increased, and finally after hundreds of charge, discharge cycles will be compromised.

3.       If we find the poor performance of the battery, the battery must be replaced. Replacing batteries must be professional execution.

4.       The battery should not be individually replaced, should follow the overall replacement battery supplier’s instructions.

(B) Battery maintance

1. The ambient temperature maintanined at 20 to 25 degrees celsius:

2. The best in the first month for 2 to 3 cycles charging and discharging.

3.After the first month, every 3 months, discharge and charge once.

(C) Alarm 1:  low voltage battery

   Alarm will sound in the following condition:

1. The battery voltage is too low:

2. Battery run time lower than the set schedule.

(D)Alarm 2: Output overload

 Refers to the rated overload power output is too large, that percentage of the value greater than 100%, if the value of 0 peak load current is too large, then the inverter will alarm. When the inverter alarm, need to reduce the total value of the inverse calculation.

(E) Alarm 3: Overheating or fan failure

   When the inverter control system, inverter power, rectifier power module caused by overheating situation due to environmental temperature or fan failure.

Note;

1.       Shut down the inverter and keep it far away from the mains electricity before replacing the batteries.

2.       Take off like rings, watches, metal objects and so on.

3.       Use a screwdriver with insulated handle, don’t put tools or other metal objects on the power.

4.       When connecting the battery cable, a small spark occurs in the joints is normal, will not cause harm to personal safety and inverter.

5.       Don't shorten the battery or reverse polarity!

 

 

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

View History

vedio center products center Honor Knowledge Outstanding Articles
Bluelight History  |  About Us  |  Honor  |  Knowledge  |  Feedback  |  Service  |  Company profile  |  Contact Us

© 2005-2019 Wellsee solar supply Copyright, All Rights Reserved.
Wuhan Wellsee New Energy. Block D, Zhongli Enterprise Building, No. 92, Wuhan Boulevard, Wuchang District, Wuhan, Hubei, China
Tel: 0086-13986203125,13986203097,13971182531 E-mail: sales@e-bluelight.com,admin@e-bluelight.com
skype:Cindy
cindywellseeCindy cindywellsee  skype:Doris
doriswellseeDoris doriswellsee  skype:Tracy
tracywellseeTracy tracywellsee  skype:Owen
sarawellseeOwen sarawellsee
Run 115 queries, spents 0.229150 seconds, 11 people online,Gzip enabled,take up memory 4.399 MB